We all know that what compels an organization, institution, or company to use such devices and equipment is the occurrence of unpredictable events in the server room, which can cause a major crisis for the IT manager. For example, the failure or burning out of the server room cooling system leads to a temperature rise above 40 degrees Celsius, which can cause servers or storage devices to burn out or, in the best case, cause the network to shut down. Therefore, the manager installs a system for temperature, humidity, and environmental factor monitoring and alerts so that in case of an incident, they are informed and have the opportunity to react promptly to prevent further incidents. So far, this is completely logical, but if the server room alert system, for very technical reasons, fails to react promptly during an incident, does not send alerts, or issues false alarms when there is no incident, can such a system still be used at any cost? Certainly not.
Perhaps the reader wonders why the smart server room system might fail to issue timely alerts or give false alarms. The answer to this question is in the two lines below:
The manufacturer knowingly produces the hardware with low quality to increase profit and offer a more competitive price, despite knowing these issues occur in real conditions.
Or the manufacturer unfortunately lacks the academic or practical expertise to build such a system and is a company involved in all IT and network commercial affairs, relying on Chinese or miscellaneous companies to produce a system under its own brand.
In both cases, the seller causes problems and even troubles after purchasing an unreliable product. This leads to numerous issues whose scope is evidently very broad.
In the SRC2.2 server room monitoring system, you can experience the following features along with the highest level of stability. In designing control systems, besides sending alerts upon errors and displaying information online and offline and recording data, another capability is added to the system so that, when needed, alongside monitoring various errors, hardware reaction definitions can be set.
In the smart server room system, logically defined outputs correspond to each error to resolve problems as much as possible without human intervention. These errors in the server room temperature alert system can include the following; in other words, in environmental control systems for server rooms, besides the below items that are monitored and alerted to the user, control relays are also connected to the outputs.
The device capabilities can be summarized as follows:
Display temperature data online and offline
Display humidity data online and offline
Record temperature and humidity with adjustable time intervals
Log login and lockout counts with date and time
Define access levels
Receive alarm and error files independently from temperature and humidity data
Receive login and lockout files from the smart server room management software
Export data to Excel in both Solar Hijri and Gregorian calendars
Display information on industrial monitors
Display information on computer monitors
Send error alerts to manager and maintenance personnel mobile phones
Define error terms as desired
Define the number of received errors as desired in server room temperature control
Add new sensors such as smoke and fire, unauthorized entry, and water leakage to the server room control system
Send local error alerts and siren flashers
Send error alerts as buzzer sounds on the main controller
Error alerts as pop-ups
Error alerts by lighting LEDs
Automation and smart control of cooling systems (package units, air conditioners, split units, chillers)
Automatic reaction capability in case of cooler failure or air temperature rise affecting the cooling system
Define alert texts distinctively according to error type
Set temperature setpoints within acceptable ranges by the server room manager
Define the type of alert sent for each error independently
Support for 8 additional temperature sensors on one controller
Unlimited installation of additional smoke and fire sensors
Unlimited installation of power outage sensors
...and many other features and alerts you may never have encountered or heard of are available in this system.
For complete product information, visit this link:https://pishrans.com/src2-2
To see project photos, the following link will help:https://pishrans.com/photo-project
To see the names of organizations that have worked with this company, use the next link:https://pishrans.com/projects1
If you want more information about server room sensors, see the next link.
There are no comments for this product
| Company | پیشران صنعت ویرا |
|---|---|
| Tel | +98 21-4×××3681, +98 21-4×××5128, +98 21-4×××5809, +98 21-4×××583 |