This device immediately sends an alert via SMS or missed call to the manager or responsible personnel upon temperature or humidity increase.
Upon temperature rising beyond the danger range, it initiates a special process to control the temperature or shuts down the server to prevent damage.
When temperature exceeds the allowable range, it activates sirens or warning lights.
It can receive commands from the manager via mobile phone under any conditions.
Displays current temperature and humidity.
Can connect to all existing sensors: fire, smoke, water leakage, unauthorized entry, impact, power outage, UPS failure, input voltage fluctuation, voltage level increase or decrease, single or two-phase cut in three-phase systems, and power outage of the server room monitoring device itself.
Capable of monitoring the temperature inside server racks and environmental conditions of the server room via mobile phone.
All alarms such as temperature and humidity increase, smoke presence, water leakage, cooler shutdown, compressor or condenser issues like gas leakage and cooling failure, unauthorized entry, and severe power fluctuations are notified on mobile.
Has automatic control capability for coolers or server room ventilation automation.
Sends SMS notifications to users in case of power outage.
Sends alerts in case of two-phase network occurrence.
Intelligently manages the cooling system to reduce load and wear.
Can record temperature and humidity data for up to 10 years and plot temperature and humidity change curves.
Can be connected via Ethernet port for command and system control.
Includes scheduled cooler rotation to ensure equal wear.
Can activate reserve coolers if any existing cooler fails.
Can turn on coolers after power outage and restoration.
Supports normal operating time based on each cooler's capacity to reduce service and maintenance costs.
Utilizes a wide range of protective sensors in the room to enhance system security.
Allows defining alarms separately for each sensor.
Can receive sensor temperature data from various smart server rooms on mobile.
Can send audio and video alerts to security with a separate display.
Audio and visual alarms for any error in the server room.
Notifies about power outage and restoration times.
Can control and monitor all analog sensor parameters.
Supports manual and automatic cooler control for easy maintenance without changes.
Download product cataloghttps://pishrans.com/images/pdf/src.pdf
Displays full system status on industrial panel (HMI).
Displays temperatures and humidities on industrial panel (HMI).
Can retrieve current alert status via mobile.
Can retrieve current temperature and humidity via mobile.
Server room temperature and humidity data logger with monitoring capabilities: WEB BASE, WIN BASE, IP BASE.
Supports parallel controller system.
Can add hardware monitors for server room temperature and humidity control.
Can remove hardware monitors.
Has server room control and crisis management capabilities in emergencies.
Network power cutout system in case of fire.
Manual and automatic control of split or cooling systems.
Complies with TIA942 protocol.
Internal communications designed as secure Modbus.
Has reliable and trustworthy PLC hardware.
Includes automated electronic equipment check system.
Allows simultaneous control from multiple points in organizational network.
Comprehensive management system enabling monitoring of all covered server rooms in one control room.
Supports touch screen monitoring panel connection for security and units in smart server room management.
Has reliable industrial hardware.
Modular hardware allows quick repair services when needed.
Communication protocol with computer is TCP/IP; sensor communication uses Modbus.
Has synchronization mechanism with computer.
Does not issue false or unrealistic errors for the server room.
Can operate at high temperatures in the server room.
Reporting available in both Persian and Gregorian calendars.
Generates server room temperature and humidity reports in Excel format with charts over defined time intervals.
Provides independent alarm and warning reports unrelated to temperature and humidity.
Provides independent reports on system login counts.
Output charts and graphs support size and scale definition.
Allows defining allowable ranges for each sensor individually.
Allows defining alert types (siren, SMS, email) for each sensor individually.
Full article linkhttps://pishrans.com/src2-11 Resume linkhttps://pishrans.com/projects1 Project photos linkhttps://pishrans.com/photo-project
There are no comments for this product
| Company | پیشران صنعت ویرا |
|---|---|
| Tel | +98 21-4×××3681, +98 21-4×××5128, +98 21-4×××5809, +98 21-4×××583 |
| Whatsapp link | |
| Instagram page | |
| Telegram | Telegram link |
| Website | http://www.pishrans.com |
| Country | Iran |
| Province | Tehran |
| Address | تهران –بزرگراه ستاری جنوب به شمال-بعد از حکیم –نبش کوچه اسدی –پلاک41 –واحد 10 |
Jooyeshgar AI Assistant