-
در بخش Sell Offers، دسته بندی Air conditioning systems، Province Khuzestan موردی پیدا نشد.
دسته بندی Air conditioning systems را امتحان کنید.-
Hisense inverter split duct
single ventilation\r\n\r\nHisense inverter channel split duct\r\n\r\nHisense split duct technical specifications\r\n\r\ncooling and heating function\r\nequipped with inverter kit \r\nsuper low consumption \r\nSuper silent\r\nHas a rotary compressor\r\nHas R410 gas\r\nHas a wall-mounted touch thermostat\r\nAbility to install a spa coil\r\nImported full pack\r\n\r\nHisense ultra-low consumption split duct and it is completely silent.\r\nHisense split duct is completely imported and has a valid Caspian gold warranty. Other parts\r\n\r\nAsk us for the best price of Hisense Split Duct.\r\n\r\nShipping to the whole country\r\nReasonable price\r\n\r\nFor more information, contact our experts. Please %\r\n\r\n09126625754
Air conditioning systems Tehran -
Mushroom fan exhaust - ceiling fan exhaust
Exhaust fans are used to move air and discharge stagnant air or polluted air. One of the types of exhaust fans is the mushroom or ceiling type, which is known by this name because of its appearance.\r\nWe at Azin Industrial Group Ventilation We produce two models of ceiling ventilators, one is a mushroom exhaust fan with a round cap and the other with a flat protective cap. To know its specifications, you can visit https://www.azintahvie.com/.\r\nInformation about The price and dimensions of the device 09194201355\r\n Mushroom fan exhaust or ceiling fan :\r\n Ceiling fan exhaust or roof fan exhaust, which are also known in the market by other names such as ceiling fan and mushroom exhaust fan, are one of the types of industrial suction fans. And it is air conditioning equipment for different places which is very widely used, this type of suction like exhaust spiral fans is very widely used in residential, office and commercial buildings and towers, industrial and semi-industrial factories, hospitals and... The reason for choosing mushroom ventilators is because they occupy little space and this type of suction can be used. installed directly on the channel or the outlet valve on the roof. Ceiling ventilators are more useful in places that require less pressure, and usually in places where the flow rate and static pressure are relatively high, it is recommended to use a centrifugal fan exhaust instead of a ceiling ventilator. Utility type ventilation with a backward propeller should be used, one of the factors that causes the ceiling fan to be used is the lower price compared to the spiral type exhaust fan, at the same time, due to the lack of sufficient space and the lack of need for a ducting network in many places, the use of Ceiling or roof fan exhaust can be a very good choice. More information in the following articles. http://61c9a45cf09b7.site123.me/ https://azintahvieh.blog.ir/
Air conditioning systems Tehran -
Rapele positive pressure fan
Ventilation fan or positive pressure fan is used to enter fresh air into production halls and indoor spaces. Ventilation fans have many applications that can be used in air conditioners and air washers or in filters. Boxes used it, but one of the most important applications of double pressure fan is positive pressure in firefighting and for stairs. Positive pressure fan is one of the most essential tools for maintaining the security of new buildings. Today's buildings have become so large and crowded that residents in an emergency can not quickly reach the emergency exits and may get stuck in the building. To eliminate the risk of people being trapped inside buildings, air pressure fans are installed on the stairs of buildings so that when smoke and fire are created, these fans can create an exit space for people. Positive pressure fan has different models and applications that are designed and produced by Azin Ventilation Group. You can visit https://www.azintahvie.com/ to buy different types of suction and blowing fans.
Air conditioning systems Tehran -
Smart Boiler Room Control
## Smart Boiler Room Traditional boiler rooms are in an unfavorable condition regarding energy losses in ventilation systems, therefore they require factors that enhance the boiler room's ability to optimize energy. Some common methods have been heard so often in society that there is no need to mention them; one of these is insulation. But is everything that can be done about energy losses limited to insulation? The answer to this question is no. In [smart boiler rooms](https://pishrans.com/office-location/%25D8%25A7%25D8%25AA%25D9%2588%25D9%2585%25D8%25A7%25D8%25B3%25DB%258C%25D9%2588%25D9%2586-%25D8%25B3%25D8%25B1%25D9%2585%25D8%25A7%25DB%258C%25D8%25B4) new intelligent mechanisms are used to apply factors that reduce energy consumption. This intelligence causes: 1- The boiler room to operate less and have lower wear and tear 2- The boiler room to operate less and consume less energy 3- The boiler room to operate less and have lower maintenance costs The method of smartening boiler rooms is the same, but the algorithms and hardware used by companies differ. In the [Pishran Sanat Vira smart system](https://pishrans.com/%25D9%2585%25D9%2582%25D8%25A7%25D9%2584%25D8%25A7%25D8%25AA/1-boiler-controler) a predefined program can be set for different weather conditions. In the Pishran Sanat Vira smart system, boiler and circulation pump mechanisms can be technically alternated to reduce fatigue. In the Pishran Sanat Vira smart system, the software environment of the system can be monitored via web-based or network-based methods. In the Pishran Sanat Vira smart system, the capability to alert different boiler sensors can be implemented on the smart system. In the Pishran Sanat Vira smart system, the system can be manually operated when needed to meet the requirements of the facility staff. And many other cases... The mentioned points are only a glimpse of the features of the Pishran Sanat Vira smart system and one of the [optimization](https://pishrans.com/%25D9%2585%25D9%2582%25D8%25A7%25D9%2584%25D8%25A7%25D8%25AA/2-saving-energy) methods. For more information, please contact our consultants.
Air conditioning systems Tehran -
Modern Smoke Harcraft of Iranian Fan
### Fan Iranian Selection\r\n\r\n## with the management of Ali Mirzazadeh \r\n\r\n\r\n\r\n\r\n## ways of communicating with us\r\n\r\nSite \r\nhttp://gozidehfaniranian.com\r\n\r\nWatts Up / Telegram 98919372561\r\n\r\nFactory \r\n\r\n982136445252\r\n982136424453\r\n982136428992\r\n@ Iniesta Gram Telegram Gozidehfan-iranian\r\n\r\nEmail email: gf.iranian1152@gmail.com\r\n\r\n\r\n\r\n\r\nThe largest manufacturer of wind ventilation in Iran with the best quality\r\nTwo -head bearings of galvanized sheet\r\n## Wind ventilation\r\n\r\nAmong the most consumed fans in industrial factories and niches. Warehouses. Carriers. Business/Residential Complexes. Due to the need for electrical energy, the wind ventilation fan can be mounted on sloping or flat surfaces and uses the wind force. The winds are designed and manufactured so that even if the rain vent is constant, the rainwater will not enter the canal and location.\r\n## Using wind ventilation\r\n\r\nSuitable for air conditioning of industrial halls of livestock poultry farms.\r\nTested for various purposes, bringing fresh air into the workplace to control moisture and creating an unpleasant air.\r\nOutside and by entering clean air in the environment, it ensures health and environment.\r\n\r\n\r\nIranian fanfare wind ventilation without the need for electrical energy and ...\r\n\r\n\r\nExcerpts from Iranian Technology\r\nWind ventilation sizes\r\nIt is from 10 cm to 100 cm at the request of esteemed customers\r\n\r\n### Modern (Japanese) fans \r\nModern (Japanese) chimney (Chinese) (Cottage) is one of the most practical types of fireplace and chimney warheads that are attracted to construction architects and customers due to their unique design. Depending on the structure and design, it is easy to install and is compatible with most environments. In addition, it is a good option to obtain approval from the Gas and Engineering Organization. Japanese warheads prevent the air from returning into the building and preventing insects and particles from entering the chimney.\r\n\r\n### Damper \r\n Inter -channel\r\n Balance Wind Weight\r\n Fire anti -fire \r\nDamperors are vital components in air conditioning, heating and cooling systems used to control air flow in channels and ventilation systems. These devices help improve system efficiency, adjust the temperature and humidity, and reduce energy consumption by accurately adjusting and controlling airflow. The dampers are generally made of blades or blades that adjust the air flow rate by changing their angles.\r\nDamperors can be made in various forms and types, each suitable for specific applications. For example, motor damper is used to automatically adjust the air flow in complex air conditioning systems, while manual dampers are usually used in simpler systems and in places that do not require frequent adjustment.
Air conditioning systems Tehran -
ODANA X8100 air conditioner protector and 10 amp battery
Odana model X8100+ air conditioner protector and 10 amp package, made in Iran\r\nAs its name suggests, the voltage protector has the task of protecting electrical appliances against voltage fluctuations, so that when the voltage is less than 175 volts and more than 240 volts, it cuts off the electricity so as not to damage the device that consumes electricity.\r\n\r\nOdana voltage protector model X8100+ is directly connected to the power outlet without connecting wire and has only one house (outlet) of 10 amps. On the protective body of the Odana package, there are three lights as described by Dale:\r\n\r\nRed color means power cut (voltage less than 175 and more than 240 volts).\r\nThe orange color means to prepare to reconnect the current with a delay of 4 to 6 minutes if the voltage stabilizes within the permissible range.\r\nGreen color means ready-to-use air conditioner protector.\r\nYou can buy a 10 ampere package protector and air conditioner with a 3-year warranty from the exclusive store of Sain Electronics in Tehran.\r\n\r\nTechnical Specifications:\r\nAn earthed socket\r\nVoltage 175 to 245 volts\r\nThe maximum power that can be supported is 2450 watts\r\nMaximum transmission current 10 amps\r\nPolyamide material\r\nHas internal brass fittings of 5 tenths for nuts\r\nHas external brass connections of 7 tenths for earths\r\nElectronic board resistant to instantaneous start up to 16 amps\r\nDimensions 65*96*150\r\nWeight 280 grams
Air conditioning systems Tehran -
Intelligent Boiler Room System
## Intelligent Boiler Room System The intelligent boiler room system is one of the systems used worldwide to reduce energy consumption in central boiler rooms. Due to its intelligence, this system operates with minimal energy consumption in the boiler room, and the boiler room maintenance experiences less operational wear and tear. For this intelligence, control systems and precision instruments are used, which result in optimal switching on and off in residential, office, commercial, and even industrial boiler rooms. The main functions of the intelligent boiler room system are classified as follows: 1- Reducing the boiler room temperature during increased outdoor temperature conditions for greater savings 2- Reducing the boiler room temperature during off-peak boiler room usage hours 3- Reducing the boiler room temperature during holidays of administrative, commercial, and industrial centers 5- Complete shutdown of the boiler room one hour before closing and two hours before starting work 6- Complete shutdown of the boiler room on holidays 7- Ability to disable the intelligent system and manually control it 8- Ability to activate or deactivate a boiler or pump and ............. Read more information on the company's website Project links and company resume https://pishrans.com/projects1 Photos of some projects https://pishrans.com/photo-project
Air conditioning systems Tehran -
Parking Ventilation Damper - For F300 Exhaust System
A damper is a device used to control and adjust the flow rate of air passing through a duct, which is categorized into various types. One of these types is the double-blade dampers with low leakage. The primary use of these dampers is for places where controlling the leakage of air or fluid passing through is important. The most common discussion of this is in parking garages. In multi-story parking garages where smoke and fire control systems are considered, low-leakage dampers (double-blade) must be used for the exhaust dampers on each floor so that in case of fire, the smoke leakage through closed dampers is minimized. For fresh air intake dampers, it is not mandatory to use low-leakage dampers like double-blade ones; V-shaped blade dampers can be used. However, in both types of dampers, the body and blades must withstand fire temperatures for a duration of 2 hours. Regarding the motors allowed for dampers in parking garages, according to the new fire department regulations for these dampers and the fresh air intake dampers in parking garages, the use of dampers with spring return mechanisms is not permitted. Therefore, according to this requirement, smoke control damper motors without spring return and on/off damper motors can be used. Designers suggest using smoke control damper motors without spring return for exhaust dampers and regular on/off damper motors for fresh air supply dampers. Our recommendation is to use Lufberg smoke control damper motors without spring return and with position switch, code: FS10N220S, which is a 220-volt model. For fresh air intake dampers, use Lufberg regular on/off damper motors with torque ratings of 4 and 8 Newton-meters (for dampers under 0.7 square meters and under 1.4 square meters respectively): DA04N220, DA08N220, both 220-volt models. Both models are also available in 24 volts, but the 220-volt version is more commonly used. An important note for employers is that the term F300 is mistakenly used for parking dampers. This designation applies to parking exhaust fans and related duct accessories, meaning they can withstand 300 degrees Celsius for 2 hours. Although the damper body in parking dampers can withstand this, this is not specified for damper motors. None of the damper motors installed on dampers from any brand can withstand this temperature. Damper motors typically withstand 50 degrees Celsius during operation and 80 degrees Celsius during storage (there are a few special cases that can withstand 117 degrees, but these are not imported into Iran). According to the Tehran Fire Department, as of summer 2019, all spring-return-free motors for parking garages are approved. However, it is better to verify with this organization before approval and procurement of these motors. For consultation, supply, and manufacturing of these equipment, please contact: 09303383322 02186034976 Thank you, Hemati Lufberg Parking Parking Ventilation Electric Damper Fire Damper Lufberg FS10S220ST FS05SS220ST FS10N220S DA04N220 DA08N220
Air conditioning systems Tehran
Similar Products
-










