In this system, logically defined outputs correspond to each error so that problems can be resolved as much as possible without human intervention. These errors can include the following:
After sounding the alarm and sending an SMS, the backup cooler in the network turns on, and if the temperature does not decrease with the backup cooler, a critical condition alarm is sent to the manager.
This rarely happens because increased humidity usually occurs when the cooling system is off, and according to calculations, humidity trends decrease as temperature rises in a system, so this issue is practically ruled out. However, having a humidity sensor is a security factor for higher protection levels in the system.
In this case, after sending an alert, if a generator or UPS system exists, it will start cooling.
In very large systems where cooling relies on water circulation, water leakage can damage the entire system. If leakage is detected, water inlets and outlets at the site can be closed to prevent damage, and finally, the main power to the server room is automatically cut off at the source (main fuse) to avoid short circuits.
In industrial three-phase equipment like UPS and similar devices, two-phasing can cause UPS burnout, which can be neutralized by cutting off all network power.
Sometimes, due to a short circuit in high-voltage lines, the neutral wire becomes energized, allowing 380V to enter the network. This can severely damage all input components such as UPS and devices connected to the main network power. In such cases, the incoming power must be cut off immediately, which can be done by controller systems.
In this case, after activating the alarm and sending an SMS, the system should effectively block the unknown person by shutting off electrical inputs or outputs.
If this occurs, it has irreversible consequences and indicates a fire in one or more locations. Electrical systems in the server room must be immediately disconnected from the power network, and air production sections turned off to reduce oxygen and help extinguish the fire.
This happens when the server room cooling, including split units, has clogged water drainage, causing water to be sprayed into the air by the coolers. Sometimes this water drips onto racks, causing severe damage and equipment burnout.
In intelligent server room systems, controlling cooling and compressor rotation to reduce fatigue, calculating cooling operation times, and automatic system troubleshooting elevate server room control to the highest available level.
It is worth mentioning that the Pishran Sanat Vira intelligent server room system is the only PLC-based system in Iran compliant with TIA942 standards.
Read more on the company's main website:https://pishransata.com/src3-1/
Read articles about server room standardization here:http://B2n.ir/p97512
See our customers here:https://pishransata.com/projects/
There are no comments for this product
| Company | پیشران صنعت ویرا |
|---|---|
| Tel | +98 21-4×××3681, +98 21-4×××5128, +98 21-4×××5809, +98 21-4×××583 |
| Whatsapp link | |
| Instagram page | |
| Telegram | Telegram link |
| Website | http://www.pishrans.com |
| Country | Iran |
| Province | Tehran |
| Address | تهران –بزرگراه ستاری جنوب به شمال-بعد از حکیم –نبش کوچه اسدی –پلاک41 –واحد 10 |
Jooyeshgar AI Assistant