  • 5 Year

The G790 control relay is protected for controlling gas burner with refractory frame and polycarbonate frame. This controller is completely electronic, and a guide LED, the reset button and the base button on the top.
Technical Information:

• Source voltage: 220V (180 to 250V)
• Fuse: Quick 10 A or 6A
• Consumable power: 3VA
• Maximum flow of each base: 4A
• Maximum output current: 6a
• Early discharge time: approximately 40 seconds
• Insulation Standard: IP44
• Early spark time: 3 seconds
• Delay time returning to initial settings after turning off: 2 seconds
• The permitted temperature around the relay: -10 ° C to 60 ° C
• Net weight: 180 g
• Installation mode: Optional
Important points
• Before applying, wiring must be carefully examined. The cause or misconduct in wiring and wiring can be dangerous and cause irreparable damage. Note that if the G790 relay relay replaces another relay (other than G790), the wiring may be changed.
• When applying the controller, the connection screw must be solid to ensure the full connection of the G790 controller to the relay base.
• Proper fuse is mandatory in accordance with the technical specifications of the controller. In addition, the main fuse (s) should be selected in such a way that they operate and cut off the electricity before the current reaches the relay values ​​in the relay technical specifications. Otherwise, at the time of the short circuit in any part of the burner equipment, there may be severe damage to the controller, torch components or user.
• For safety reasons, each G790 controller must be turned off at least once every 24 hours.
• To install and/or remove the G790 controller relay must be cut off and the torch be separated from the feeding system.
• The G790 Relay Controller is a precise and high -safety electronic device and is manufactured for the safety of the torch and its user system under the supervision of Electronic Company experts. Please avoid opening or repairing it.
Relay performance test
If the controller or torch repairs are opened and closed, the following measures must be taken by the experienced server of the torch before the usual use of the controller:
• First check all connections in terms of leakage, wiring, strength and lack of vibration.
• The following tests should only be performed by experienced people and all safety -related measures and prevention should be performed when performing the test.
• Before performing any of the following tests, the power and fuel of the burner must be connected and cut off after the test.
Test One: (This test is performed by closing the main valve (manual) of the fuel) The controller launches the spark after the discharge phase, and after the assurance time goes into the error phase. (Press the reset button to exit the error phase.)
Test 2: Open the main fuel valve and set up the torch to establish a flame. After a few moments of the burner, re -close the fuel valve. The controller goes to the error phase. (Press the reset button to exit the error phase.)
Third test: in the function of the torch and the establishment

There are no comments for this product

Installations 26

  • Company registration date: -
  • Number of staff: 1-10 Person
  • Company activities: Shop
  • Place: Iran, Province Tehran
  • In the field of: ابزار دقیق و اتوماسیون
  • Company Type: Private


Contact Info: Installations 26
Companyتاسیسات 26
Tel +98 21-8×××5487 callMake Call
Mobile +98 936×××8796 callMake Call
CountryIran
ProvinceTehran
Addressتهران –خیابان طالقانی خیابان بهار شمالی پاساژ مرجان طبقه زیر همکف واحد 32 0936-1808796 021-88495487 021-88495467 26tasisat@gmail.com
Send pm Company Profile
FAQs

Do you have any question about this product?

The latest products in this category
Jooya
Jooya

Jooyeshgar AI Assistant

Press Enter to send, Shift+Enter for new line