Filter Sell Offers:

Sell Offers Audio and Video Province Chaharmahal and Bakhtiari

  • در بخش Sell Offers، دسته بندی Audio and Video، Province Chaharmahal and Bakhtiari موردی پیدا نشد.
    دسته بندی Audio and Video را امتحان کنید.
      Similar Products
      • Telecom and SCADA between electrical substations and a study of the structure and how to communicate in DPLC DG CCHP, CHP

        Telecom and SCADA between electrical substations and a study of the structure and how to communicate in DPLC DG CCHP, CHP

        - Introduction: به because of the extensiveness of the network of interconnected production and transmission in the electricity industry and the scattering of the stations in the points, sometimes out of reach, launching and roughing telecommunication systems of the basic needs of the industry, the electricity industry. Land uses major telecommunication in the electric power industry include : 1 - the transfer of information and send commands auto-protective to isolate sections of injured and defective in the shortest time and avoid the extensiveness of the minor accidents to the entire network and the Prevention of possible accidents. 2 - transfer information collected from posts and power plants to centers of control and transfer commands to the control from control centers to the stations. 3 - coordination of operation and communicate between departments, staff and operational through the network, telephone, independent power. سیستم communication used in the network, telecom, power industry, included wireless, etc. microwave oven, ETC., PLC, ETC., DTS., the fiber optic system, and switching. - PLC system telecommunication is that of lines of high pressure at the frequency of 40 to 400 kHz for the transfer of messages, telecommunication uses. - DTS network dedicated Hot Line Telephone دیسپاچینگ can be. - cable OPGWدر power transmission lines, instead of the Earth Wire for data transfer with the volume and security of the most used. سیستمPower Line Carrier is one of the modern methods of data transfer, which is its acronym PLC, but not the controller logic programmable, but power transmission lines. توسعه resources, production, transmission and distribution of electrical energy need urgently to the existence of a network between key points power system, like the Centers of production, conversion, decision-making and distribution, mostly at intervals far apart, actually have been there. Transmission lines can be used to send the waves of frequency above the carrier information in the system of telecommunication used. System that for this species the transfer of information used in the tool, \\\"transmission carrier wave, the information on the system pressure, strong\\\" or PLC is called. موارد under the necessity of creating a network Telecommunications PLC to clear the track: 1 - network, telecom, public respond to the communication needs of the direction of the effective operation of the network, strong pressure is not. 2 - تبادلاطلاعات between the Centers of دیسپاچینگ and other پستهاتوسط a شبکهمخابراتی مطمئنو dedicated, from the necessities of such centers can be. 3 - use a comprehensive network of telecommunication, posts can to protective equipment equipped with a return that makes the ability to trust more and effective operation of the network can be. 4 - the lack of a network dedicated to. the weakness of communication via network, telecommunications, telecommunications company, the lack of access the majority of posts located outside the city, to the lines of communication PTT problems are that if there is a network, make sure the sides have to be exploited more efficiently from the network it creates. با pay attention to the tips above, the direction of Upland, the bugs listed and operation of the grid, can be used سیستمهایPLCچنین networks of Telecommunication for use in networks power supply design. استفاده from the PLC instead of other communication systems, such as cable, telephone, etc. radio waves and microwaves, and ... has benefits that can include : 1 - due to the insignificant being, the drop signal carries information in each area. the Centers of production and distribution of electrical energy, usually at intervals away from each other واقعند can be straight by Ka ...

        Audio and Video Tehran
      • HAVER BOECKER ROTO PACKER and VENTOMATIC repairs

        HAVER BOECKER ROTO PACKER and VENTOMATIC repairs

        Repairs of electronic equipment in the loading bay of HAVER cement and petrochemical factories and VENTOMATIC\r\n\r\n\r\n ****************** HAVER MEC III DISPLAY ******* *******\r\n1- Repairing the rotary display of Packer Haver loading warehouse MEC III DISPLAY brand Haver & Boecker Mehriz Tejarat Cement - Shahrekord Cement - Nizar Qom Cement - Torbet Zaveh Cement and...\r\n\r \n *************** HAVER MEC III CPU Modul ***************\r\n2- Repairing the CPU module of the rotary packer machine MEC III CPU Haver loading dock brand HAVER & BOECKER Shahrekord cement, Nizar Qom cement, Lar Sabzevar cement, Urmia cement, Saman Gharb cement and ...\r\n\r\n ************ **** HAVER MEC III A/D Modul ******************\r\n3- Repairing the A/D module of the Haver rotary packer loader MEC III A/D MODULE HAVER & BOECKER brand Shahrekord cement, Nizar Qom cement, Lar Sabzevar cement, Saman Gharb cement, Urmia cement and ... ****************** HAVER MEC III I-O MODULE ******************\r\n5- Repairing the I/O module of the rotary packer Haver loader MEC III I/O MODULE brand HAVER & BOECKER Cement Shahrekord, Cement Nizar Qom and ...\r\n\r\n ****************** HAVER MEC II LCD MEC II-20 ************** *\r\n6- Repairing the display of the Haver rotary packer display MEC II 20 display MEC II 20 brand HAVER & BOECKER Cement Gharb, Hegmatan Cement, Bushehr Dashtestan Cement and ...\r\n\r\n7- Repairing MEC II wage brand HAVER & BOECKER Farazfirouzkoh Cement, Bojnord Cement, Farazfirozkoh Cement, Mazandaran Cement and ... HAVER MEC II CPU 5-099-0249-10 HAVER MEC II POWER1 5-099-0149-13 HAVER MEC II CALIBRTE 5-099-0599-13\r\nHAVER MEC II SERVER 5-099-0689-16\r\nhaver MEC II wage\r\n\r\n8- Repairing the display of the rotary packer loader EWU/010 VENTOMATIC FLSmidth brand Urmia Cement, Estehban Cement, Fars Cement, Benavid Cement, Kerman Cement, Parsian Cement and...\r\n\r\n9- Repairing the display of the BT-15 rotary packer and haver loader, brand HAVER, Nayin Cement, Saroj Isfahan Cement and . ..\r\n\r\n20 years of experience in the field of electronic equipment repairs, all types of drives - soft starters - chargers - power cards and electronic equipments\r\n\r\nRehavard Andishe Electronics Company\r\nThe company was registered in 1381 With economic code, national ID and official invoice \r\nwww.rahavardelectronic.com

        Audio and Video Tehran
      • UNI-T UT33D+ digital multimeter

        UNI-T UT33D+ digital multimeter

        Unity UT33D+ Pocket Digital Multimeter The new generation of the UT33+ series defines performance standards for entry-level digital multimeters. Drop-resistant up to 2 meters, the new LCD screen layout provides better user experience. Users can work in CAT II 600V environments without any problems. UNI-T UT-33D+ is a small, inexpensive and high-quality multimeter. This product code can measure alternating voltage up to 600V, direct voltage up to 600V, alternating and direct current up to 10A.\r\n\r\n\r\nTechnical Specifications:\r\n- Measurement capability:\r\n Alternating voltage (AC) up to 600V\r\n Direct voltage (DC) up to 600V\r\n Direct current (DC Current) up to 10A\r\n Resistance up to 200MΩ\r\n\r\n - Diode test capability\r\n - Test probe holder\r\n\r\n - Safety level: CAT II 600\r\n - Ability to display numbers up to 2000\r\n - LCD dimensions: 66mm*51mm\r\n - Device dimensions: 131mm*95mm*58mm\r\n - Net weight: 473g

        Audio and Video Tehran
      • Engineering documents required for the construction of CHP, DG and CCHP power plants and distributed generation and small scale generators

        Engineering documents required for the construction of CHP, DG and CCHP power plants and distributed generation and small scale generators

        این شرکت توانایی تولید تمامی مدارک زیر را به طور کامل دارد: 1Electrical document  Basic design • Equipment Data Sheets and Technical Specifications. • P&I diagram for the system. • Calculations for cable sizing according to the Site Conditions. • Power distribution scheme. • Controls, instrumentation, alarms and protection scheme and write up. • over all key single line Diagram (Detail Design) • MV switchgear single line Diagram • Main LV switchgear single line Diagram • MV switchgear data sheet • LV switchgear data sheet • Main transformer data sheet • Aux transformer data sheet • Generator NGR data sheet • Generator protection&metering&synchronging Single line diagram • Load flow & short circuit study • MV & LV cable list • Battery charger & ups single line Diagram • Battery charger & ups data sheet • MV switchgear logic diagram • LV switchgear logic diagram • Single line diagram of generator metering & protection. • Dimensional layout and sectional drawings for the complete scope of work (including pipe and cable layout). • Schematic and wiring diagram of Battery charger. • Dimensional General Arrangement Drawing of various equipment along with Cross - Section and bill of material. • Layout and mounting arrangement of battery. • Any other drawings/document deemed necessary by the Employer. • Generator curves and characteristics. a) O.C & S.C Characteristics. b) \\\"V\\\" curves. c) Reactive capability curves. d) Generator transient and sub-transient reactance. e) Generator losses, fixed and variables. f) Communication non-interference test curves. g) All other necessary curves for the generator, exciter, AVR and auxiliaries. • Characteristics curves for Pumps and Natural Gas Engines. • Where ever applicable Speed Vs Torque Curve of the pump corresponding to recommended mode of pump starting, superimposed on speed Vs torque curve of the motor corresponding to 80%, 90% and 100% rated voltage. • Selection of D.C. battery and charger rating. • Calculations for net electrical output at site after deducting power consumption of D.G. auxiliaries. • Write-up on specific features of equipment, if any. • Control Philosophy for whole the power plant including Grid interconnection. (SCADA System) • Other Data and Documents required for proper and on time completion of the Contract but not mentioned hereinabove.  After award of contract and during the Project Engineering Phase detailed design • Final version of all data/drawings/schematics/calculations as specified above. • Arrangement of generator phase and neutral terminals. • Wiring diagram of local control panels, D.C. battery charger etc. • Relay setting calculations for generator relays. • Any other drawing/document/data deemed necessary by the Employer. a) Write up on operation, control and monitoring of D.G. plant. b) Cable interconnection diagram and cable schedule. • To be submitted for Approval (A)/Reference (R) and Subsequent Distribution:  Transport/shipping dimensions with weights, wheel base detail etc. (R)  Terminal arrangements of Generator (A)  Rating and Diagram Plate (R)  Cable Interconnection Diagram and Cable schedule (R)  Drawings of major components like starting system, fuel system, local control panel etc. (A)  Detail manufacturing and supply schedule (A)  Power distribution scheme (A)  Controls, instrumentation, alarms and protection scheme and write up (A)  Write up on Voltage regulator and governor (R)  Single line diagram of generator metering & protection (A)  Preparation of dimensional electrical layout of DG electrical building and sectional views showing disposition of electrical equipment, arrangement of cable trays/ cable rack in cable spreader room and also interconnection with respective DG set and Grid Interconnection. (A)  Schematic and wiring diagram of Battery charger (A).  Dimensional General Arrangement Drawing of various equipment along with cross - Section and bill of material (A).  Layout and mounting arrangement of battery (A).  Generator curves and characteristics as mentioned in “Generator curves and characteristics” above.  Where ever applicable Speed Vs Torque Curve of the pump corresponding to recommended mode of pump starting, superimposed on speed Vs torque curve of the motor corresponding to 80%, 90% and 100% rated voltage (R).  Selection of D.C. battery and charger rating (A).  Calculations for net electrical output at site after deducting power consumption of D.G. auxiliaries and for DG sizing.  Write-up on specific features of equipment, if any (R).  Arrangement of generator phase and neutral terminals (A).  Wiring diagram of local control panels, D.C. battery charger etc.(R).  Relay setting calculations for generator relays (R).  Any other drawing/document/data deemed necessary by the Employer (R).  Write up and logic diagram on operation, control and monitoring of D.G. plant (R).  Any other relevant drawing or data necessary for satisfactory installation, operation and maintenance (R).  Other Data and Documents required for proper and on time completion of the Contract but not mentioned hereinabove. 2 Mechanical document 1. Engine document 1.1. Adjusting, trouble shooting, testing 1.2. Contamination control guidelines 1.3. Disassembly and assembly 1.4. Operation and maintenance manual 1.5. Parts identifications 1.6. schematic 1.7. specifications 1.8. tool operating manual 1.9. torque specifications 2. Gas Engine stack calculation 3. Gas Engine stack arrangement 4. Gas Engine cooling system calculation 5. Gas Engine cooling system p&id 6. Gas Engine cooling system arrangement 7. Gas Engine cooling system arrangement 8. Gas Engine cooling system equipment data sheet 9. Gas Engine cooling system piping plan 10. Gas Engine cooling system piping MTO 11. Gas Engine cooling system piping isometric 12. Gas Engine natural gas piping plan 13. Gas Engine natural gas piping MTO 14. Gas Engine natural gas piping isometric 15. Gas Engine ventilation system calculation 16. Gas Engine ventilation system p&id 17. Gas Engine ventilation system arrangement 18. Gas Engine ventilation system equipment data sheet 19. Gas Engine Mechanical installation details 3 Civil document 1 Civil Design Criteria 2 Structure Design Criteria 3 Drainage Design Criteria 4 Specification For Earth Works 5 Specification For, Storm Sewer And Oily Water Sewer 6 Specification For Fencing & Gates 7 Specification For Gravel Paving 8 Specification For Reinforced Concrete paving 9 Specification For Asphalt Concrete paving 10 Specification For Excavation, Trenching And Backfilling For U-G Utilities 11 Specification For Concrete Works 12 Specification For Fabrication And Erection Of Steel Structures 13 Specification For Base Setting & Grouting Of Equipment 14 Specification For Anchor Bolts 15 Specification for Building 16 Specification for fireproofing 17 Typical Drawing For Fence & Gate 18 Typical Drawing for Anchor Bolts 19 Typical Drawing for Hand Rail 20 Typical Drawing for Ladder 21 Typical Drawing for Stair 22 Typical Access Platform 23 Typical drawing for fireproofing detail 24 Typical drawing for Roads 25 Typical drawing for Oily Water & Domestic Sewer Manhole 26 Typical drawing for Catch Basin 27 Typical drawing for Valve Pit 28 Typical drawing for Cable Trench & Duct Bank 29 Typical drawing for Surface Drainage Ditches 30 Typical drawing for Concret Paving 31 Typical drawing for Underground Crossing 32 Typical Details for Architectural Drawings 33 Topographical Plan 34 Soil Investigation Report 35 Rough Grading Longitudinal & Transverse Profiles 36 Finish Grading and Surface Drainage Plan & Section 37 Electrical &Intrument Cable Trenchs Plan & Section 38 Civil Composite Plot Plan 39 Foundation Location Plan 40 Landscape Plan & Details 41 Drawing for Pipe Supports 42 Calculation Note for Pipe Supports 43 Architectural Drawing for Power House Building 44 Structural Drawing for Power House Building 45 Foundation Drawing for Power House Building 46 Calculation Note for Power House Building 47 Architectural Drawing for Control & Administration Building 48 Structural Drawing for Control & Administration Building 49 Foundation Drawing for Control & Administration Building 50 Calculation Note for Control & Administration Building 51 Architectural Drawing for Workshop and Store Building 52 Structural Drawing for Workshop and Store Building 53 Foundation Drawing for Workshop and Store Building 54 Calculation Note for Workshop and Store Building 55 Architectural Drawing for Switchgear Building 56 Structural Drawing for Switchgear Building 57 Foundation Drawing for Switchgear Building 58 Calculation Note for Switchgear Building 59 Architectural Drawing for Gate Keeper Building 60 Structural Drawing for Gate Keeper Building 61 Foundation Drawing for Gate Keeper Building 62 Calculation Note for Gate Keeper Building 63 Architectural Drawing for Fire water pumps shelter 64 Structural Drawing for Fire water pumps shelter 65 Foundation Drawing for Fire water pumps shelter 66 Calculation Note for Fire water pumps shelter 67 Foundation Drawing for Gas Engine Generator Set and relevant Auxiliaries System 68 Calculation Note for Gas Engine Generator Set and relevant Auxiliaries System Foundation 69 Foundation Drawing for Diesel Generator package 70 Calculation Note for Diesel Generator package Foundation 71 Foundation Drawing for Transformers 72 Foundation Drawing for Fire water pumps 73 Calculation Note for Fire water pumps Foundation 74 Foundation Drawing for Fire Water storage tank 75 Calculation Note for Fire Water storage tank Foundation Foundation Drawing for Other Equipments

        Audio and Video Tehran
      • BGA IC assembly with

        BGA IC assembly with

        device Automatic and manual electronic board assembly with guaranteed quality as soon as possible with experienced staff and high work experience. BGA IC assembly with BGA Machine. I assembly C BGA, BGA IC disassembly, BGA IC Rebal. Massage of ICs, QFP, TQFP, QFN and .... Assembly of various SMD and DIP components with industrial, medical and .... Perform QC and test assembled electronic boards. Assemble all types of cables and connectors including Circular, Amphenol, SMA, SMB, RG, BNC, etc. Electronic board design, reverse engineering Assembly Module and rack system assembly Supply of original electronic components from the most reputable companies in Europe and China. Order PCB manufacturing from the most reputable companies in China and Taiwan Delivery in the fastest time and with a guarantee Address: Tehran-District 9 Moin Ostad Blvd., Hashemi St. BGA, SMD assembly, PCB assembly, dip board assembly, dip smd board assembly, electronic board assembly, montage ژ dip and smd, assembly of electronic components, assembly of electronic board

        Audio and Video Tehran
      • Four-axis USB Mach3 controller board with 100KHZ output pulse

        Four-axis USB Mach3 controller board with 100KHZ output pulse

        The four-axis CNC controller board uses powerful MACH3 software and can control a maximum of 4 stepper motors simultaneously. The wrist CNC controller board uses a USB port. Suitable for connecting to laptops and new systems Mach3 controller is a PC Base based controller and has all the features that a powerful controller needs. 4-axis wrist CNC controller board to build a router CNC, laser router, etc. Areas of application The four-axis wrist CNC controller board is suitable for all types of small and medium automation equipment and equipments, such as engraving machine, strip machine, marking machine, cutting machine, laser machine, Medical equipment, CNC machine tools, automatic assembly equipment, electronic processing equipment ... Support for 3-axis or 4-axis connection, you can connect four stepper motor drivers or servo drivers Maximum stepping pulse frequency 100 kHz, which is suitable for servo motor or stepper motor Water support Automatic probe field Emergency input support Limit switch support (or 3-wire PNP Proximity switch) Electronic cart connection support To separate USB and external port and stabilize the system, you must Use 24V DC external power supply. It has an output port of 0-10V, you can use mach3 software to control the speed of the spindle motor. 4 General purpose input, you can use limited switch, stop switch, Connect the probe switch, return to zero and other devices. 4 All-purpose isolated relay drive output interface, can have four relays to control spindle start, forward rotation and reverse rotation, pumps and other devices Drive slowly. 1 The status LED shows the connection status on the board. Technical specifications: External voltage: 24/12 volts Operating frequency: 100KHz Support: 4-axis The maximum phase pulse is 100 kHz, which is suitable for motors and servo motors From probe tools Automatically supports Exit port for spindle control 0-10V has emergency input "0102 030405 "Controller board, CNC controller board, CNC controller board, four-axis controller board, MACH controller board, four-axis CNC controller board" 0102030405 "

        Audio and Video East Azarbaijan
      • owon 100 MHz 4-channel oscilloscope

        owon 100 MHz 4-channel oscilloscope

        Four-channel 100 MHz digital oscilloscope (super economical) model SDS-1104 made by OWON company\r\n\r\nThe cheap four-channel oesioscope is easily portable due to its engineering design and ultra-slim and light body (1.1 kg). SDS1104 model scope has the ability to communicate with programming and data control applications such as SCPI and LabVIEW. In addition, it has two USB 2.0 Host and USB Storage Device ports to save up to 20k waveform points. An oscilloscope is a type of electronic test tool that graphically displays various signal voltages as a function of time. The characteristics of the displayed waveform such as amplitude, frequency, rise time, time interval, distortion and other things can be analyzed by this scope. At first, the calculation of these values ​​was done manually by CRO analog scopes and scales embedded in its screen. While modern digital oscilloscopes such as SDS1104 calculate and display these characteristics directly.\r\nThe oscilloscope is used in medical science, engineering, automotive and telecommunications industry, maintenance of electronic equipment and laboratory work, analysis of the car ignition system or showing the waveform of the heartbeat as an electrocardiogram.\r\n\r\nTechnical Specifications:\r\n- 4 channels\r\n- 4 props\r\n- 100 MHz bandwidth\r\n- 8bit resolution\r\n- Digital and memory\r\n- Super slim body\r\n- Sampling speed 1GS/s

        Audio and Video Tehran
      • Reverse engineering of electronic boards

        Reverse engineering of electronic boards

        Making electronic cards by reverse engineering method Making FME-L001 SCHENCK FMEL001 card for cement factories Schenck Multicont remote unit FME L001 Making Schneck FEA-L001 I / O card SCHENCK FEAL001 for cement factories I / O MODULE Making HERWEG VIBRATO card by reverse engineering method for cement factories Making George Fisher card for Tabriz Tractor Manufacturing Making HAVER & BOECKER relay packer card for cement factories Making filter bag card for cement factories Making sorter sticker card 3-10-863 For ceramic tile factories Making JDG2 card for Kaveh glass crystal Making JDG3 card for Kaveh glass crystal Making PXI 1850 card for Kaveh glass crystal \ r Making PXA1990A card for Kaveh glass crystal Making PXI1890 card for Kaveh glass crystal Making R81053 card for Kaveh glass crystal Making TJB card For Kaveh glass crystal Making TE983333 card For Kaveh glass crystal Making TE0983307 card For Kaveh glass crystal Making OLI card VOTTO 103 for Kaveh glass crystal Make BERNARD CI2701-1A card for Kaveh glass crystal Make BERNARD CI2701-2A card for Kaveh glass crystal Make BERNARD card GamK for Kaveh glass crystal

        Audio and Video Tehran
    Audio and Video