Filter Sell Offers:

Sell Offers information and communication technology Province Lorestan

  • در بخش Sell Offers، دسته بندی information and communication technology، Province Lorestan موردی پیدا نشد.
    دسته بندی information and communication technology را امتحان کنید.
      Similar Products
      • Next-generation native IP firewall system (IPImen NGFirewall-UTM)

        Next-generation native IP firewall system (IPImen NGFirewall-UTM)

        The next generation firewall (IPImen Next Generation Firewall) produced by Takian company, is presented from the ground up on the platform of the customized operating system by this company called ImenOS (based on FreeBSD distribution Unix). Due to the design at the Kernel level, this product is able It performs firewalling with high stability and a much higher speed and has been successful in obtaining the approval of Fata for many years. takian.ir/ipimen-ngfw has discussed the description and specifications related to this product.

        information and communication technology Tehran
      • Web server room temperature control

        Web server room temperature control

        Web server room temperature control is a system that is able to display the environmental factors of the server room that cause damage to the room online anywhere on mobile and desktop and the manager To be aware of its occurrences But what kind of temperature monitoring is suitable for the server room? Companies and organizations that use server equipment within the organization are always concerned about what system is appropriate to protect the room and server equipment in the event of an error. Answer to this question by the Electrical and Electronics Association (ieee The Association of Electrical and Electronics Engineers publishes information in various journals, the most famous of which is tia942 server rooms. The summary of the material that has been correctly stated and translated by the server room regarding the security and protection standards of the server room. 1) In order for the monitoring and warning system to be a stable system, it must be possible to The most reliable hardware to use for this is plc hardware. 2) Sensors used to measure analog parameters of temperature and humidity must send information with the Modbass protocol. 3) Used digital sensors to measure the presence or absence of a hazardous physical quantity such as water leakage or smoke They must be independent of the length of the wire. The provider does not have any dependence on the servers, even the internal servers and its own computer to send alerts or error notifications. 6) The modem system has a hardware connection with the alarm mechanism and continues to operate independently of the server section, which can send alarms without interruption in case of non-functioning and down servers. 7) The controller system regularly checks its internal mechanisms, including monitors, sensors and GSM modems, to troubleshoot and repair any problems before the above defect causes a crisis. These There are seven khans that are not available in every server room temperature and humidity monitoring and control system, but you can find all of the above in SRC2.2. http: // pishrans.com/src2-2"0102030405 "Server room temperature monitoring, server room monitoring software, server room control and monitoring system, server room monitoring equipment, server room monitoring device, server room temperature alarm system" 0102030405 "

        information and communication technology Tehran
      • Buy cheap home mobile antenna amplifier

        Buy cheap home mobile antenna amplifier

        Today we are faced with mobile antenna problems and lack of internet speed. Some telecommunications masts are far away, signal traffic, frequency disturbances in the transmitter have caused us to not receive a good signal. The home mobile antenna amplifier is one of the best radio communication equipments to solve the problem of mobile antennas, which receives the received signals by the receiver antenna, amplifies it by coaxial cables and transmits it to the transmitter antennas. This will increase the quality of conversation and the speed of 3G, 4G, 5G mobile internet. ✅ For more information about inexpensive home amplifiers, contact Kian Telecom experts. ⭕ Services of Kian Telecom Company: Designing RF boards Installation of radio equipment ✅ Repairing all types of mobile antenna amplifier devices Selling all kinds of booster antennas

        information and communication technology Tehran
      • Server Room Control and Monitoring System

        Server Room Control and Monitoring System

        SRC2.2 A server room temperature and humidity control and monitoring system that can protect the server room from unexpected events This system that is formed An industrial controller that is responsible for the primary processing of information Auxiliary industrial controller that plays the role of inputs and outputs a hardware modem that is responsible for sending alerts on mobile phones via SMS A siren used for local alarm An temperature and humidity sensor capable of measuring temperature and humidity items and sending them to the main controller The package has the ability to protect the server room against a sudden increase in temperature and humidity, and in various ways local sirens - flashers - mobile alerts - software pop-ups - email alerts can alert users of the dangers Other sensors that can be added to the above package in this system are All types of warning sensors 1) Temperature sensor 2) Humidity sensor 3) Network power outage sensor 4) UPS disconnection sensor 5) Smoke increase sensor 6) Water leak sensor 7) Server room door open sensor 8) Non-entry sensor Allowed to server room 9) Rack shock sensor 10) Power oscillation sensor 11) Rack temperature sensor 12) Split temperature sensor or air conditioner failure sensor 13) Battery drain sensor 14) Rack door opening sensor 15) Cooler compressor burn sensor 16) Condenser frost sensor 17) Cooler fuse cut-off sensor 18) Sensors malfunction warning 19) Fire sensor 20) Ignition prevention sensor 21) Zero wire load sensor 22) Network biphasic sensor 23) Dust increase sensor 24) Sensor Refrigeration system gas outlet 25) Sensor increase or decrease of mains voltage from the allowed range If you want to know more about sensors, the following link will help you https: // b2n. ir / b96748 In addition, the above system has the ability to provide services under Windows and under the web, and outside the organizational space, access to the server room status is available Also the time of occurrence of events and Return time b Their normal state in this system is stored on the memory installed in the device and can be seen at any time Meanwhile, the output graph of the system is able to display the values ​​of temperature and humidity and display them within a specified time range More of all the above, the most important thing is that this system is completely designed and built by an Iranian company, and sanctions and the problems caused by them will not cause any disruption in the supply of parts or services or maintenance. This issue has been proven to all customers in the last few years and can be cited For more information about this product, refer to the following link http: //pishrans.com/src2-11 If you wish See snake portfolio This link is useful http: //pishrans.com/photo-project If you want a resume and project history, see it here http: //pishrans.com / projects1 If you have any questions or need technical advice, please contact us via this link http: //pishrans.com/contact-us

        information and communication technology Tehran
      • 1K PVC Mayfer Card

        1K PVC Mayfer Card

        Technical Specifications of Mayfer Card Mayfer Card is used in many systems. According to the above result, we have 47 blocks, each with a capacity of 16 characters. Each sector It has 4 blocks Block0 to Block3 Print of all rfid card models for ease of identification and use. The smart cards provided by Pars Processor Company are in 3 types: Memory without memory (read only) Single ID card printer with the ability to upgrade to double card printing system (Double Side, Single Side) Best Mayfer 1k card. Card with 1 KB memory (readable and writeable) Quality Print 300dpi / 11.8 MillionColor How to print Mayfair Magnetic PVC card. Cards with 4 KB memory (readable and writeable) This type of card is also known as Contact Less. Applications: 1- Traffic control systems for people (entry and exit) and cars (parking lots) Each 1 kB card has 16 sectors Sector0 to Sector15 The mentioned block card type and serial number There is a card that can only be read set . Given that we have 16 sectors and each sector has three blocks that can read and write 54 = 2 - 64 = 4 * 18 500 cards (packed in 5 packages of 100) 3 .375 \\\\\\\ "X 2.125 \\\\\\\" (85.6 mm X 54 mm) If we notice that there remains a block in each sector, this block (block3) is dedicated to Key B, Key A which are the passwords of each sector Pvc Mayfer card production method. CR80.030 (CR8030) Size - thickness 30 million, standard credit card size System Credit cards that can be used in the subway, bus tickets, sports and entertainment complexes, etc. Printing on all types of cards (.... Magnetic, PVC, PVH, ABS, PET, RFID, Contactless, smartCard,) Counter of printed cards (Counter) Except for sector zero, block zero, it is possible to enter data in all blocks 0, 1 and 2 of each sector.

        information and communication technology Tehran
      • Monitoring of environmental conditions of server room

        Monitoring of environmental conditions of server room

        Temperature and humidity control system src2.2 is the latest product of Vira industry drivers in the field of automation of environmental factors of server room as well as automation of server room ventilation. This system is due to at least 30 changes in recent years. From the beginning until now, a lot has changed and in these changes, a lot of updates and innovations have been made. The main factor in controlling the temperature of the server room or controlling the environmental conditions of the server room is the stability of the monitoring system. The system is resistant to factors such as electrical and electromagnetic noise - temperature increase - increase and decrease in humidity - increase in dust - increase in smoke or materials such as sudden disconnection and do not have problems and did not fail. Unfortunately, it is not easy to distinguish a stable system from an unstable one, and any technical assembly can build a server room temperature monitoring and control system with a little knowledge, because practically building such equipment in a laboratory will not take much time or facilities. A laboratory model that gives data on a table under normal conditions Will it provide a critical situation? Finding the answer to this question is a very difficult task for IT professionals because they do not interfere in the field of control and precision instruments, so we must refer to the documents and evidence and extract the result from it. 1) The first condition for building such a system is to have an academic infrastructure with roots, and this infrastructure can be extracted from the company's articles of association, so that if the company starts to build the articles of association of the control and tools unit Not to be outdone, this system will certainly cause many problems in the future. It is encouraging to mention that oil companies, due to having experts in various fields, put companies on their vendor list that have passed these filters due to their instrumentation and control. 3) The third condition for navigating to This is the use of Iranian services and equipment because experience has shown that companies that work as agents (there is currently no official representative in Iran) or They use external tools and equipment for service and maintenance in all conditions, whether with or without sanctions. They have many problems and transfer these problems to the employer. The above technical and quality evaluation factors have come out proud and are ready to be tested with any type of benchmark. This system has the following technical specifications and facilities: Technical specifications 1) The main controller is industrial plc 2) The air conditioner controller is industrial plc 3) The main display is industrial hmi 4) gsm modem is used industrial type 5) Box Industrial polycarbonate with ip54 degree of protection 6) Temperature sensor is industrial type with modbus rtu protocol 7) Humidity sensor is not industrial type with modbus rtu protocol 8) Industrial power cut sensor from Italian finder type is used 9) Industrial smoke sensor and relay type is used and .................... ................... ............................... ..... Types of alarm and system alarm methods src2.11-src2.11 + src1.9 1) Alarm on the spot Audio (guard or caretaker) 2) On-site flash alert (guard or caretaker) 3) On-screen alarm as a warning sign 4) On-screen alarm as Led light 5) On-site alert in the form of a clear voice 6) Computer screen alert in the form of popup 7) Computer screen alert in the form of led 8) Mobile alert in the form of SMS S 9) Alert on email 10) On-site alert in case of color change Graph bar 11) Alert as misscall Ability to separate alerts Each Which of the above warnings can be used or deleted in any of the following cases? ) Email alert 4) Miss Call alert on mobile Safety feature 1) Automatic health test of temperature and humidity sensors 2) Automatic health test of hmi display 3) Automatic health testing of gsm modem Methods of recording and retrieving information and errors 1) Recording and retrieving temperature measurement in the entire period used 2) Recording and Humidity recovery of the place during the whole used period 3) Record and display defined errors other than temperature and humidity 4) Receive information recorded with the solar and Gregorian calendars 5) Separate registration of the system control panel entry and determine the entry method 6) Draw the temperature change curve And humidity System connection methods 1) Communication using the application under Windows tcp / ip 2) Communication using the web server 3) Communication using mobile Special controller capabilities 1) Control of 1 to 4 air conditioners simultaneously 2) Ability to move active air conditioners with reserve air conditioners to reduce mechanical fatigue of air conditioners 3) Crisis period (one air conditioner is intelligently replaced by another due to malfunction) Until the temperature reaches its desired value) 5) Ability to manually operate the air conditioners in software and hardware at the required times (repairs) 6) Power system independent of the air conditioner control system 7) Ability Connection to humidifier to reach the required level of humidity in the server room 8) Fully modular design for generalization Easier to maintain and in less time 9) Ability to record information 8 rack temperature sensors and 2 ambient temperature and humidity sensors 10) Schedule timer to enter during authorized and unauthorized hours \ r. ..

        information and communication technology Tehran
      • Server Room Temperature Alarm System

        Server Room Temperature Alarm System

        Thc400 is a server room alarm that can alert users to various observable alarms in the server room because the server rooms are damaged in various incidents. The device has multiple inputs for measuring factors. These items are different: 1) Temperature 2) Humidity 3) Smoke 4) Fire 5) power outage 6) water leakage 7) unauthorized entry 8) unauthorized traffic 9) gas 10) power fluctuation 11) UPS interruption 12) battery discharge and other sensors that It can check the critical condition of the server room and in case of an unfortunate event, inform the managers and maintenance staff of the server room. The notification methods can be siren, flasher, miss call, SMS, and even in the event of an error, the ability to play a recording message. This system is able to use alerts to send alerts to audiences that are not in place, which are 1) fixed telephone line 2) Mobile phone line (SIM card) System connection f Considering the fact that there is an independent or central telephone wire in the server room, in addition to the alarms that it generates in the form of sirens and flashers, it can create alerts in the form of voice messages or alarms in case of danger. Absence of physical presence at the server room or the relevant organization and company can still be alerted, and this warning and warning is done through a landline. Equipping this system with a SIM card also allows users who do not have a landline in the server room or have problems to provide it by equipping a SIM card inside the device to be able to operate when updated Even if they are not present at the organizational location, they should be informed of the incident. Using the SIM card, in addition to calling the user by phone, they can even send an SMS to the user so that in the event of an event, the user can Be aware of what happened. The dual methods of warning and notification by SMS and Miss Call can make this possible for work Make sure that even if you do not know the charge of the SIM card inside the device (if the SIM card is valid) and it is completed by Miss Call, which does not need to be charged, you can be notified of what happened inside the server room. Also in server rooms where it is possible to have a fixed telephone line, connecting this line to the device can make the information process safer in terms of safety, even in cases such as 1- SIM card expiration 2- Interruption of SMS notification methods by operators 3- Damage to GSM 4- Removing the SIM card and forgetting Relocating it The server room is still not communicated from the point of view of communication without a platform The main mechanism of this device is a modem that has multiple sensors and temperature and humidity controllers and their displays. It is connected and its job is to inform, but alarm detection methods are performed by sensors that have continuous values ​​such as temperature and are measured by a controller, or sensors such as smoke that are digital in nature and alert you if a certain amount is increased. . Temperature measurement mechanism Temperature measurement, which is a physical quantity and is constantly changing, is performed by industrial temperature controllers. These controllers have the advantage that due to their stability, they have effects. The environmental parameters on them are low and they almost never get errors or wrong measurements. Another advantage of industrial controllers is the presence of monitors that are responsible for setting the temperature of the alarm and normally the temperature The server room current is displayed. This display, which is shown as a digital digit, reduces the possibility of incorrect reading or visual error to zero. The standard maintenance temperature of the server room is 18 to 22 ° C, which should not exceed this value. Inside the server rooms below 18 degrees is not only a problem but also an advantage and only the increase of temperature above 22 degrees is worrying and above 30 degrees is dangerous and above 35 degrees is critical and can cause any kind of incident for servers and storage. Increase temperature sensitive to view other models of alarm systems R & n temperature controller visit Pishran Sanat Vira website www.pishrans.com

        information and communication technology Tehran
      • bms Intelligent server room system

        bms Intelligent server room system

        src2.2 Server room environment monitoring system In this system, there will be a logical definition in the output for virtually any error so that problems can be solved as much as possible without manpower. These errors It can be such things as the following: 1) The temperature rises After turning on the siren and sending an SMS, the reservation air conditioner turns on, and if the temperature does not decrease With the backup cooler, the alarm sends a critical situation to the manager. 2) Humidity increases And according to the calculations, the trend of humidity changes in a system will decrease with increasing temperature, so this issue is practically eliminated, but the presence of humidity sensor is a security factor for a higher degree of protection in the system. 3) In this case, after sending the warning, if there is a generator system or UPS for cooling, it will start cooling 4) water will leak In very large systems where the cooling task is handled by a rotation process B. Water leakage can cause damage to the entire system, which in case of water leakage can close the inlets and outlets of water from the desired location so that the leakage does not cause damage, and in the end the electricity of the entire server room from the source (main fuse) Automatically disconnect to avoid connection 5) The power of the system is 2-phase In industrial equipment, 3-phase, such as UPS and similar, 2-phase network can burn UPS can cause this to be neutralized by cutting off the entire network power 6) The single-phase network becomes 2-phase Sometimes due to connection In high-voltage power lines, the neutral wire is also energized and 380 volts of electricity enters the network. This can cause severe damage to all input components such as UPSs and devices that are connected to the mains power, which In the event of this happening, the input to the system must be cut off without delay, which can be done by control systems 7) Unauthorized entry into the network is done In this case, after activating the siren and sending the SMS, the system must be in front of an unknown person Can close electrical outlets or inlets 8) Sudden increase in temperature in the area This event has irreparable consequences and indicates a fire in a Or there are several places that should be immediately disconnected from the electrical network without interruption of the server room electrical systems and the air production sections should be turned off so that the lack of oxygen helps reduce fires. 9) Sudden increase in humidity in the place without Temperature This factor occurs when the cooling of the server room, which includes the split, clogs the water duct and the water created in the coolers is blown into the air by the coolers themselves, which in some cases this water is on. The racks fall and cause severe burns and damage to the equipment In intelligent server room systems, control of cooling and relocation of compressors to reduce fatigue and calculate cooling operating times and automatic troubleshooting of the system by itself The ability to control the server room To the highest level available It should be mentioned that the Vira industry forward system is the only plc-based system in Iran that is in line with tia942 standards Read more information on the main website of this company https: //b2n.ir/x80305 Read the information about server room standardization articles here http: //B2n.ir/p97512 See our customer information here https: //pishrans.com/photo-project

        information and communication technology Tehran
    information and communication technology
    Price list and manufacturers of information and communication technology equipment, including fiber optic joint, various types of fiber optic fusion equipment, passive equipment, fiber optic equipment, site design